9.3.- CirLAMP Node 1 ... 10 V
AC power supply
Mode Self-powered
Rated voltage 184 ... 276 V ~
Frequency 50/60Hz
Consumption 2W 16VA
Installation category CAT III 300 V
Voltage measurement circuit
Voltage measurement margin 184 ...276 V ~
Input impedance 600 MΩ
Installation category CAT III 300 V
Current measurement circuit
Current measurement margin 0.1 ... 3A
Minimum measurement current (Istart) 0.08 A
Installation category CAT III 300 V
Measurement accuracy
Voltage measurement < 5% of full-scale
Current measurement < 5% of full-scale
Active and reactive power measurement < 5% of full-scale
Outputs 1 ��� 10V (In accordance with EN60929:2011)
Output voltage 1 ... 10V
Current 10μ ... 2 mA
PLC (Power Line Communications)
Hardware CENELEC B DCSK
Baud rate 2400 bauds with repeater management
Protocol CirPLC (DCSK)
Insulation
Alternating voltage 4 kV RMS 50 Hz for 1 minute
Overimpulse
1.2/50 μs 0R source impedance 2 kV UNE-EN 61000-4-5:2007 + CORR:2010
Environmental features
Operating temperature -25ºC... +70ºC
Storage temperature -35ºC... +80ºC
Relative humidity (non-condensing) 5 ... 95%
Maximum altitude 2000 m
Protection degree
IP65
Mechanical features
Dimensions (mm) Figure 101
Weight 250 gr
Enclosure Polycarbonate
94
CirLAMP system
Instruction Manual
Komentarze do niniejszej Instrukcji