parameter has been activated or not.
When the dripping parameter has been activated, the assigned energy is stored in the EDA
tank constantly (every second) and at a rate proportional to that of the contracted energy.
When the dripping option has been deactivated, Compact Dispenser mode, energy is trans-
ferred once a day.
The unit opens the general relay when the balance of EDA units is depleted or when the system
has been tripped due to an overcurrent.
To recover the power supply, the customer must wait until the EDA tank is lled by means of
transferring units from one tank to another or by charging it with EDA units purchased from the
DISPENSER-SOFT operator.
If the EDA balance is used up and the tank is filled after activating the dripping option, the gen-
eral relay will be automatically rearmed, following a reclosing sequence that varies according
to the times the power supply has been cut off during the day (See 5.2.4.1.- GENERAL RELAY).
This type of contract can have no denite time limit, Open-ended contract, with no additional
costs included in the price of energy. Designed for buildings that are not charged for the use
of energy, such as cultural centres, churches, etc.
3�5�4� - TYPE 4 CONTRACT: EDA FLAT RATE
Figure 18:Hydraulic diagram of Type 4 contracts�
24
Dispenser Universal System
Instruction Manual