EDS
M98237501-03-13A
5.- Technical specifications
- Single-phase (phase – neutral) A1 – A2 :
- Frequency:
- Maximum consumption:
- Working temperature:
- Water content (non-condensing):
85…264 V
ac
/ 120…300 V
dc
47…63 Hz
5…8 VA
-10 …+ 60 ºC
5 … 95 %
- Type:
- Maximum switching power:
- Maximum switching voltage:
- Maximum switching intensity:
- Electrical life (250 Vac / 5 A):
- Mechanical working life:
Relay
750 VA
250 V
ac
5 A with resistive load
3 x 104 operations
2 x 107 operations
- Case material:
- Equipment protection degree:
- Dimensions (mm):
- Weight:
- Maximum operating height:
UL94 - V0 self-extinguishing plastic
IP 20
105 x 70 x 90 mm (6 modules)
250 g
- Power :
- Slaves:
- Left RJ45 led:
- Right RJ45 led:
Equipment power supply and CPU activity
Communicating slave devices shutdown
Green: Full duplex / Yellow: Half duplex / Activity
Green: 100 Mb/s / Yellow: 10 Mb/s / Link
- Type:
- Maximum activation current:
- Insulation:
Voltage-free opto-insulated (dry contact)
50 mA
1500 V
- Type:
- Characters:
- Back lighting:
2 lines, alphanumeric
20
Yes
- Type:
- Connector:
- Network protocols:
Ethernet 10BaseT / 100BaseTX self-detectable
RJ45
HTTP / Modbus/RTU in RS-485 bus
Installation category Class III / EN61010 double-insulated electric shock protection class II.
Connect the device to a power circuit protected with gl fuses in compliance with IEC 269, or
M fuses, with values from 0.5 to 1A. It must be fitted with a circuit breaker switch or
equivalent device, in order to be able to disconnect the device from the power supply. The
power supply cable must have a cross-section of at least 1 mm
2
.
Standards:
EC, UL 94, EN61010-1, EN55011, EN 61000-4-2, EN 61000-4-3,
61000-4-11, EN 61000-6-4, EN 61000-6-2, EN 61000-6-1, EN 61000-6-3, EN 61000-4-5
- Type:
- Transmission speed (configurable):
- Data bits:
- Parity:
- Stop bit
Three-wire RS-485 (A/B/S)
4800, 9600, 19,200, 34,800, 57,600, 115,200 bps
8
No parity, odd, even
1 / 2
6.- Connections
DETAILS OF THE POWER SUPPLY AND RS-485 COMMUNICATION (SLAVE EQUIPMENT)
CONNECTIONS
DETAILS OF DIGITAL INPUT 4 ACTIVATION
7.- Technical Service
If you have any doubts about the operation of the unit or suspect any malfunction, contact our service staff at CIRCUTOR, SA
CIRCUTOR, SA - Technical Assistance Service
Vial Sant Jordi, s/n
08232 – Viladecavalls (Barcelona), SPAIN
Tel.: 902 449 459 (Spain)
Tel.: +34 937 452 900 (outside Spain)
e-mail: sat@circutor.es